Often Amateurs are looking for the passport scheme and the inclusion of a powerful UV lamp to erase the ROM or the manufacture of circuit boards photomethod. I copied from the original of all materials on this type of lamp i.e. for inclusion in the network ~220B and recommendations for its application.

Appointment lamps

Mercury-quartz lamps are powerful sources UV radiation and are used in medicine (for the goals of physiotherapy), biology and technology for photochemical processes, luminescent analysis, etc.

Technical characteristics of the lamps

Mercury-quartz lamps are designed for operation in alternating current with voltage of 220V, 50Hz, motor-starting devices according to GOST 16809-71.

During the first 10-15 minutes after the lamp is turned on electrical parameters change (transient mode), and then remain constant (steady state) at a constant voltage (see tab. 1). Dimensions of the lamp see hell. 1 (DRT), hell 2 (DRT) and 3 traits (DRT).

Electric parameters lamp when operating in the network AC.

Table 1

Type designation of the lamps

Cipher

Voltage,

Inrush current of lamps, And**

Cont. newstan. mode, min**

Steady state

Current, And**

Tense, the lamp, In

Power, W

DRT 230

(1,2,3)

220

60

15

3,80

70±8

230+11.5

DRT 400

(1,2,3)

220

60

15

3,25

135±15

400+20

Jack Russell 1000

(1,2,3)

220

140

15

7,50

145±15

1000+50

The inclusion of the lamps in the AC

Luminous fluxes of lamps the type of DRT in the wavelength range 240-320 NM shown in table 2.

Table 2

Bulb type

Cipher

Nominal value

Limit value

Net flow, W

Radiant flux, W

The state. sign. qual.

Category 1

The state. sign. qual.

Category 1

DRT-

(1,2,3)

24

22

20

19

DRT 400

(1,2,3)

39

37

33,5

31.8 mm

Jack Russell 1000

(1,2, 3)

128

125

110

108,0

The upper value of the radiant flux not limited.

  • L - lamp DRT
  • DB - choke
  • To - button
  • C1 is the capacitor container. 2-3 UF. for eg. 300-600V
  • C2 - capacitor capacity. 0,0003 -0,0005 UF.

Instruction manual lamps

Before installing the lamp in the instrument recommended wipe it with cotton moistened with alcohol. During operation of the lamps in closed vehicles necessary to provide adequate ventilation.

To operate the lamp is possible only with instruments provide the starting and steady state specified in tab.3. The position of the lamp during operation - horizontal, with the deviation from horizontal in both directions at an angle of not more than 10.

Precautions when working with lamps

To protect the eye from ultra-violet radiation should wear safety goggles. To use lamps for the purposes of physical therapy under the supervision of medical staff. When using lamps for other purposes should take precautions to avoid burns from UV rays of the lamp.

Lamps, broken or burned-out life, to break in a closed volume, processing 1% solution manganese-acidic potassium, to be taken away from the village item and bury it in the ground to a depth of 0.3 m.

The electrical parameters of the ballast choke.

Table 3

Lamp type

Operating mode

Start mode

Voltage, V

Current, And

Voltage, V

Current, And

DRT 230 - (1, 2, 3)

190

3,80 + 0,1

6,0

DRT 400 - (1, 2, 3)

144

3,25 + 0,1

220

6,0

DRT 1000 - (1, 2, 3)

139

7,5 + 0,1

14,0

Author: D. Marchenko, (RK3AOR), This email address is being protected from spambots. You must have JavaScript enabled to view it. ; Publication: www.cxem.net