Electronic correction device body state allows non-drug means to manage his condition.

In devices of similar purpose impact can be made through visual [1-5], auditory [6, 7], tactile [7, 8] analyzers and the use of electromagnetic channel "pumping" of the body [9-11]. Signal transmission in the latter case is usually, not energy, and at the information level. Such a mechanism of signal transmission is the most physiologic and as close to natural, which allows operating with negligible capacity to cause significant and tangible response.

At present we know quite a lot of devices and ways to rhythmic stimulation: audio, light, electromagnetic stimulation [1...11]. The proposed device and psycho-emotional correction uses electromagnetic communication channel.

The device is made on the basis of the relaxation pulse generator [14]. When consumed from a power source is negligibly small current (a few tenths of a milliampere) the device generates a very powerful short current pulses (Delta pulse). Such pulses have a high penetrating ability and is able to "seep" through the screens of great thickness.

The device operates as follows: the capacitor C1 is charged through the resistor R1 from the power source. When the capacitor voltage reaches the avalanche breakdown voltage of the transistor VT1, the instantaneous discharge of stored energy in a chain of series-connected resonant circuits L1, C2 and L2,C3,then the cumulative-discharge process is repeated periodically with a time constant T=R1C1. As a result of shock excitation of the system oscillatory circuit in the last generated damped electromagnetic oscillations. The decay rate of the oscillations is determined by the quality factor of the oscillatory circuit. Since simultaneously excited by two (or more) resonant circuit, the frequency spectrum is generated, consisting of the resonant frequencies of the circuits, the excitation frequency, the products of the interaction of these frequencies and their harmonics.

When used as cores of inductors ferromagnetic materials at the time of excitation of the oscillating circuit is the saturation of the core, in the initial moment of excitation is generated a wide range of harmonics, the level of which decreases as the attenuation of the amplitude of the first harmonic. Time changes and the quality factor of the inductor.

Oscillation circuit can be configured to odd harmonics of the original signal, which ensures the formation of a narrow Delta-pulses.

Thus, the apparatus generates deltadome pulses in the range of natural biological rhythms (in this embodiment, the device - beta-rhythms). Receiving the Delta-pulse man allegedly carried out through biologically active points and zones. Detection (reception) signals is due to the nonlinear nature of the interaction between incident on the surface of the body radiation with natural bipolarisation detecting structures, and transmission and processing of the stimulating signals are internal to the traditional TV broadcast signals.

When using rhythmically recurring (and slowly decreasing in frequency) sequences of stimulation pulses induces a state that promotes muscle relaxation, calm, better sleep, relieve stress and shock. On the contrary, increasing in frequency the pulse sequence in combination with an internal target setting (installation) of the body causing tonic effect, arousing extinct or an atrophic function of this body.

To the base of the avalanche transistor VT1 is connected touch Plate electrode (electrodes) that allows for the capacitive coupling to a common bus or bus power through the human body to control the frequency of oscillation of the relaxation oscillator pulses [14]. If the scheme impacts on the patient involved the second person (the doctor), he touch via the contactless system can control the operation of the generator. The transistor of the micro CKT patterns n-p-n can be replaced by a transistor of the micro CCT structure p-n-p to change the polarity of the power source.

The estimated parameters of the elements of the device; the original generation frequency of about 30 Hz, the resonant frequency of the first oscillating circuit - 690 Hz, second - 10,35 kHz (i.e., used odd harmonics of the driving signal). Inductor ferrite closed magnetic circuits. In order to optimize the shape of the generated pulses, the number of resonant circuits can be increased.

Attention! Before using this unit desirable consultation with the doctor.

Literature

1. Chuprikov A. P., Linev, A. N., Marcinkowski I. A. FILAT - new principle physiotherapy psycho-emotional disorder//the Tee. Dokl. Vses. nauch.-tech. Conf. "Man-machine systems and decision making". -Taganrog: Taganrog radio engineering Institute, 1989. -Pp. 157-158.
2. Shustov M. A. "Migraine" generators//Amateur Radio operator. - 1992. - Nil. - P. 20-21; Treats... light//the Radio Amateur. - 1993. - N9. - P. 20-21; Generator mood and health//the Radio Amateur. - 1994. - No. 6. - C-29.
3. Lee, A. G. Development of methods for management of special States of consciousness to reveal abilities//Parapsychology and Psychophysics. - 1993. - No. 4. in Pp. 44-61.
4. Application Of N 4015406 (Germany). Method and device for light therapy. - MKI A61N 5/06, A61F 7,00. - Publ. in 1993.
5. Application Of N 4013325 (Germany). Method of brain stimulation. - MKI AA 21/00. - Publ. 31.10.1991 G.; Applications No. 4003476, 400477, etc.
6. Application Of N 2243709 (UK). Generator type "Sukoon".- MCI AM 21/00.- Publ. in 1993.
7. Patent N 5101810 (USA). Device and method for therapeutic application of vibro-acoustic energy to the person. MCI IN 1/00. Publ. in RJ IMS 7-20-93.
8. Aut. SVID. N 160776 (USSR). A device for euthanasia and hypnosis/Ilyinsky, A. P., and Kukhtin I. MKI A61N 1/00, A61G 7/04, NS 3/00. - Publ. in B. I., 1964, No. 5.
9. Application 2-60349 (Japan). The guiding device of alpha-waves/Ken Hashimoto. MCI AM 21/02. Publ. 17.12. 1990; Requests 2-51347,2-50749,3-41193,3-55144,4-246336, 4-27868 etc.
10. Patent A1 0502919 (EP). A device to stimulate brain waves. MCI A61N 1/00, 2/04. Publ. in RJ IMS 7-4-93; Patents A1 0496196, 0495988, 0497672, 0500983 (EP), etc.
11. Aut. SVID. N 1593670 (USSR). A method for the treatment of patients with hypertensive disease/E. Y. Davitashvili//Inventor. - 1990. - No. 6. - S. 17.
12. Gorin S. A. And you tried hypnosis?-SPb.: DOE, 1995.-S.
13. Shustov M. A., Lunev V. I. Ecological relationship between components of the natural environment//proc. Dokl. IV the Region. nauch.-tech. Semin. by noosphere communication. (Noosphere communication. and ecology), 16-17.05.1991. - Tomsk: Sibnica,1991.-Pp. 14-18.
14. Aut. SVID. N 1506522 (USSR). The pulser/ M. A. Pasha. MCI NOSC 3/335.//B. I. 1989. - No. 33.

Author: M. Shustov, Tomsk; Publication: N. Bolshakov, rf.atnn.ru